EasyManuals Logo
Home>Hisense>Switch>HYJM-S01H

Hisense HYJM-S01H User Manual

Hisense HYJM-S01H
229 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #196 background imageLoading...
Page #196 background image
5.1 LIST OF ITEMS
FunctionItem
Language Setting
Date&Time
Group Register
Name Register
This function is used for language selection.
This function is used for adjusting the date and time.
This function is used for registering name of the block and group. The registrable number of letters are maximum
2 letters for the name of each block or group. It is also available to copy the name. If the group/block is
registered without name, it will be registered as “Group 1-1” or “Block 1” automatically.
The connected indoor units are checked by the central controller in the same H-NET. This function is used for
the group or block registration of them.
Schedule Setting
Schedule Timer Setting
Holiday Setting
This function is used for scheduled timer operation which is possible to set by each group or block.
This function is used for suspending the schedule operation temporarily.
The schedule operation will not be available when this function is set.
This function is used for setting irregular holidays such as national holidays.
This function is used for setting the time (by the minute), “Run/Stop” and temperature (19
°C30°C). For weekly
schedule setting, up to 10 schedule items can be set per day. I is also available to copy the setting.
Schedule Timer ON/OFF
Setting
“Schedule Timer OFF Setting” is used for suspending the schedule operation for the target group.
The schedule operation will not be available when Schedule Timer is OFF.
This function is used for a long holiday.
Alarm History
This function is used for displaying the list of alarm history that occurred in the air conditioner and the controller.
( Maximum 160 records)
Contact Information Register
Restore Setting
This function is used for editing the contents of contact information registration.
This function is used for restoring all the settings such as registered Groups (Blocks) and schedules.
Reconnection This function is used for checking of the connected indoor unit numbers in the same H-NET.
External Input/Output Setting
Two (2) external input terminals and two (2) external output terminals are equipped in the central controller.
These terminals are used for “All Groups Run/Stop” and “Emergency Stop” operations for the connected air
conditioners. The extern l output terminals are used for the operation signal output or alarm signal output of the
air conditioners which is connected to the central controller.
HYJM-S01H