CAPABILITIES
Heat
i
n
g
Capab
i
l
i
ty
s
This room air conditioner utilizes a heat pump system that absorbs
exterior heat and brings it into a room to be heated. As the ambient
temperature gets lower, heating capability will also lower. In such a
situation, the inverter work to increase compressor rpm to keep the
unit!s heating capability from decreasing. If the unit!s heating perfor-
mance is still unsatisfactory, other heating appliances should be used
to augment this unit!s performance.
s
The air conditioner is designed to heat an entire room so that it may take some time before you feel warm.
Timer operation is recommended for effective preheating ahead of the desired time.
Cool
i
n
g
and Dehum
i
d
i
fy
i
n
g
Capab
i
l
i
t
i
e
s
s
If the heat present in a room exceeds the unit!s cooling capacity (for example, if there are many people in
the room or other heating appliances are used), the preset room temperature may not be reached.
CAUTION
PROHIBITION
Do not use a stove
or any other high
temperature
devices in proximity
to the indoor unit.
For the refrigerant charge information, please refer to the outdoor unit installation manual
or specification label.
REFRIGERANT INFORMATION
-8-
REGULAR INSPECTION
PLEASE CHECK THE FOLLOWING POINTS EVERY EITHER HALF YEARLY OR YEARLY. CONTACT
YOUR SALES AGENT SHOULD YOU NEED ANY HELP.
1
2
WARNING
WARNING
Check to see if the unit’s earth line has been con-
nected correctly.
If the earth line is disconnected or faulty, unit failure or
electric shock hazard may result.
Check to see if the mounting frame has rusted ex-
cessively or if the outdoor unit has tilted or become
unstable.
It could collapse or fall, causing injury.
AFTER SALES SERVICE AND WARRANTY
WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS.
CONDITION
CHECK THE FOLLOWING POINTS
s
Do the batteries need replacement?
s
Is the polarity of the inserted batteries correct?
s
Is the fuse all right?
s
Is the voltage extremely high or low?
s
Is the circuit breaker !ON"?
s
Is the power plug inserted?
s
Do you have any power cut?
s
Is the air filter blocked with dust?
s
Is the set temperature suitable?
s
Have horizontal air deflectors been adjusted to their correct
positions according to the operation mode selected?
s
Are the air inlets or air outlets of indoor and outdoor units
blocked?
s
Is the fan speed !LOW"or !SILENT"?
When it does not operate.
When it does not cool well.
When it does not heat well.
If the remote controller is not
transmitting a signal.
(Remote controller display is
dim or blank.)
The following phenomena do not indicate unit failure.
<Operation start>
The unit is preparing to blow warm air. Please wait.
<In operation>
The outdoor unit is defrosting. Please wait.
Refrigerant flow noise in the pipe or valve sound generated when flow rate is
adjusted.
Noise generated when the unit expands or contracts due to temperature changes.
Noise generated with the indoor unit fan#s rpm changing such as operation start
times.
Noise of the motorized valve when the unit is switched on.
During heating, the operation
indicator blinks and air blow stops
Hissing or fizzy sounds
Squeaking noise
Rustling noise
Clicking noise
-9-
FROST WASH OPERATION
(FROST WASH)
indicator blinks
Noise occurred
during frost wash
operation
Frost wash operation
does not start
It does not wash when outside temperature is less than about 1 degrees Celsius or
It does not wash when the humidity in the room is about 30% or less or about 70% or
more than 43 degrees Celsius.
more.
When "FROST WASH" is done by operating a remote controller, it does not wash
Within 60 minutes after the end of "FROST WASH", "FROST WASH" is not operated
for product protection.
It is the sound that the internal machine is inflated and contracted by the temperature
change and the fin of the heat exchanger is frozen and thawed
Repeat for 1 secondǂ on and 1 second off for 10 seconds
Because "FROST WASH" can not work when operating the "FROST WASH" with
The air conditioner is operating
Outside air temperature, room temperature and room humidity are not
It has not been over 60 minutes since the end of "FROST WASH"
remote controller.
suitable for "FROST WASH"
Repeat for 4 seconds on and 1 second off for 15 seconds
Because it is not "FROST WASH" for a long time.
Operate the remote controller to operate "FROST WASH".
·
·
·
when the room temperature is less than about 10 degrees Celsius or more than about
32 degrees Celsius.
17

Table of Contents

Other manuals for Hitachi RAK-18REF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAK-18REF and is the answer not in the manual?

Hitachi RAK-18REF Specifications

General IconGeneral
BrandHitachi
ModelRAK-18REF
CategoryAir Conditioner
LanguageEnglish

Related product manuals