(1) Pressing the "POWERFUL" button will increase the temperature setting by PWSFTW.
(2) The powerful operation is for 20 minutes after setting.
(3) Operation is continued forcibly thermo-ON for 20 minutes after the powerful operation is finished.
(4) Defrost is inhibited for 20 minutes after the start of the powerful operation.
(5) Pressing the "START/STOP" button and "POWERFUL"button during powerful operation wil cancel
(6) If the sleep timer is set during powerful operation, the powerful operation will be canceled.
(7) When the powerful operation is set, the fan speed will be set to "HIGH" and the compressor's
maximum speed will be set to WMAX2 during powerful operation. The compressor's lower limit
(8) After the powerful operation is ended, the system automatically operates with the previous settings
speed is WKYMIN_PW.
used before the powerful operation.
the powerful operation.
i
i i
(1)
(2)
(3)
(4)
(5) Outdoor fan speed :
(6) Compressor start control : Same as Basic Heating operation
(7) Compressor speed :
(8)
~16
Hi
9
STARCPIL
Same as Basic
Heating operation
35

Table of Contents

Other manuals for Hitachi RAK-18REF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAK-18REF and is the answer not in the manual?

Hitachi RAK-18REF Specifications

General IconGeneral
BrandHitachi
ModelRAK-18REF
CategoryAir Conditioner
LanguageEnglish

Related product manuals