ENGLISH
Holiday Mode
REF Access Description
Default
Value
Range Steps Units Application
Notes
Holiday Mode S SC S80 M
absentYear Year 2015 - - - -
absentMonth Month 1 1-12 1 Months -
absentDay Day 1 1-31 1 Days -
absentTime Returning time 0:00 0:00 ~23:50 00:10 Min. -
absentSetting Setting Temperature 21 5 - 35 1 ºC -
- Start holiday mode No No/Yes - - (*1)
- Stop holiday mode No No/Yes - - (*2)
? NOTE
(*1): If “Holiday mode” is not operating.
(*2): If “Holiday mode” is operating.
Air Eco Offset
REF Access Description
Default
Value
Range Steps Units Application
Notes
Air Eco Offset S SC S80 M
c1RTEcoOffset Circuit 1 3 1-10 1 - (*1)
C2RTEcoOffset
Circuit 2 3 1-10 1 - (*2)
? NOTE
(*1): If Controlled circuits (LCDL)= “C1” or “C1+C2”.
(*2): If Controlled circuits (LCDL)= “Room C2” or “C1+C2”.
Room Thermostats
Available if Controller type (LCDM)= “Unit” or “Unit + Room” .
Thermostats Type (*1)
Compensation Factors (*2)
Room Temp Demand OFF (*2)
Check RT Address (*3)
Detected Circuits (*3)
Thermostat 1 (*4)
Thermostat 2 (*4)
? NOTE
(*1):Visible only if Controller type (LCDM)= “Unit”. Wireless not available only if Controller type (LCDM)= “Unit”, If “Unit+Room” forced to wired.
(*2): If Water calculation modes (Water calculation mode for circuit 1 heating (C1WC)) or (Water calculation mode for circuit 1 cooling (CC1WC)) or
(Water calculation mode for circuit 2 heating (C2WC)) or (Water calculation mode for circuit 2 cooling (CC2WC)) as not “Disabled” and (Thermostat
type (RTType)= “Wireless” or “Wired” or Central mode (COT)= “Air” or “Full”).
(*3): If Thermostat type (RTType)= “Wired” and Controller type (LCDM)= “Unit” or “Unit + Room”.
(*4): If Controller type (LCDM)= “Unit” and Thermostat type (RTType)= “Wireless”.
UNIT CONTROLLER
PMML0335A rev.1 - 04/2016
137

Table of Contents

Other manuals for Hitachi YUTAKI S COMBI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi YUTAKI S COMBI Series and is the answer not in the manual?

Hitachi YUTAKI S COMBI Series Specifications

General IconGeneral
BrandHitachi
ModelYUTAKI S COMBI Series
CategoryHeat Pump
LanguageEnglish

Related product manuals