8.6.2.7 Swimming Pool
Available if Controller type (LCDM)= “Unit” or “Unit + Room”.
Status
Setting Temperature
Offset Temperature
REF Access Description
Default
Value
Range Steps Units Application
Notes
Swimming Pool
S SC S80 M
SWP Status Disabled
Disabled /
Enabled
- - -
SWPs Setting Temperature 24 24~33 1 ºC (*1)
SWoff Offset Temperature 15 10~A 1 ºC (*1)(*)
? NOTE
(*1): If Status (SWP)= “Enabled”.
(*) Refer to the table:
Model
YUTAKI S & COMBI YUTAKI S80 YUTAKI M
(2.0-3.0)HP REST (4.0-6.0)HP 3HP REST
A A 31 36 56 (1) 36
- (1) If R134a compressor disabled (DSW4#1:ON) the setting must be 36ºC.
8.6.2.8 Complementary Heating
Available if Controller type (LCDM)= “Unit” or “Unit + Room”.
Heating Source
Electrical Heater (*1)
Boiler Combination (*2)
Solar Combination
? NOTE
(*1): Available if Heating source (HES)= “HP+Heater” or “HP+Heat.+Boil.”.
(*2): Available if Heating source (HES)= “HP+Boiler” or “HP+Heat.+Boil.”.
UNIT CONTROLLER
PMML0335A rev.1 - 04/2016
152

Table of Contents

Other manuals for Hitachi YUTAKI S COMBI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi YUTAKI S COMBI Series and is the answer not in the manual?

Hitachi YUTAKI S COMBI Series Specifications

General IconGeneral
BrandHitachi
ModelYUTAKI S COMBI Series
CategoryHeat Pump
LanguageEnglish

Related product manuals