3.3 Category 2 parameters: System Settings
Summer heating in
OTC mode
Minimum set point for the
heating and the pump will be
held on.
The outside
temperature at which
the heating will
switch off
The economy function will be
disabled if the setting for
summer heating is not 0
Diff between outside
and calculated water
supply temperature
If the calculated water
supply temperature is not
greater than the outside
temperature by this amount
the heating will switch off.
3.4 Category 3 parameters: Bolier Settings
Maximum central
heating setpoint 2)
90°C or obtained
from the boiler
40°C to 90°C adjustment in
1°C steps
55°C or obtained
from the boiler
40°C to 80°C adjustment in
1°C steps
Supply water
temperature 3)
Temperature
obtained from the
boiler (between 0°C
and 99°C)
Return water
temperature 3)
Temperature
obtained from the
boiler
Temperature
obtained from the
boiler
Between 0.0 bar and
4.0 bar
DHW storage
enabled after last
period of day
DHW storage disabled after
last period of day
DHW storage
during HOLIDAY
DHW storage
disabled during
HOLIDAY
DHW storage enabled during
HOLIDAY