Configuring Camera Settings
33
Connection
Figure 5-11 Connection Configuration Interface
Table 5-9 Connection Configurations
Parameter
Function
Max
Connection
Displays the maximum number of network connections for the same camera. The
value ranges from 1 to 20. The maximum number of connections is 20.
TCP Port The default setting is 37777. You can modify this setting as necessary.
UDP Port The default setting is 37778. You can modify this setting as necessary.
HTTP Port The default setting is 80. You can modify this setting as necessary.
RTSP Port
The default setting is 554. The RTSP stream query format is:
Main stream:
rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=0
Sub stream:
rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=1
You are required to manually enter the following four items: Username,
Password, IP, and Port.
IP: The camera’s IP address.
Port: The default is 554. You can leave this field blank if you are using the default
value.
Follow standard RTP protocols. When the encode mode is MJPEG, the maximum
supported resolution is 2040×2040.
HTTPS HTTPS is enabled by default. To disable HTTPS, clear the check box.
HTTPS Port The default setting is 443.