LYNX Touch Installation and Setup Guide
- 50 -
Programming the Control
Program System Settings (Continued)
SCREEN ACTION
Backlight Timeout
No
Select “Backlight Timeout”. The System toggles between No and 30 Seconds.
Quick Arm
Yes
Select “Quick Arm”. The System toggles between Yes and No.
Quick Exit
Yes
Select “Quick Exit”. The System toggles between Yes and No.
Restart Exit Time
Yes
Select “Restart Exit Time”. The System toggles between Yes and No.
SIA: The L5200/L7000 default is “Yes”.
Force Bypass
No
Select “Force Bypass”. The System toggles between Yes and No.
UL installations: must be NO (no forced bypass)
Exit Warning
Yes
Select “Exit Warning”. The System toggles between Yes and No.
SIA: The L5200/L7000 default is “Yes” and is not selectable.
Auto Stay Arming
Yes
Select “Auto Stay Arming”. The System toggles between Yes and No.
SIA: The L5200/L7000 default is “Yes”.
Lack of Usage Notify
Disabled
Select “Lack of Usage Notify”. The System scrolls between the following options:
Disabled
1 Day 90 Days
7 Days 180 Days
27 Days 365 Days
Power-Up In Previous
Yes
Select “Power-Up In Previous”. The System toggles between Yes and No.
Note: If the previous state was Armed Away or Stay, the system will not respond to sensor changes for
1 minute. This allows time for sensors such as PIRs to stabilize.
UL installations: must be Yes (power up in previous state)
SIA: The L5200/L7000 default is “Yes” and is not selectable.
Display Alarm Cancel
Yes
Select “Display Alarm Cancel”. The System toggles between Yes and No.
Display Exit Time
Yes
Select “Display Exit Time”. The System toggles between Yes and No.
Cross Zone Delay
None
Select “Cross Zone Delay”. The System toggles between the following:
None
30 Seconds
1 Minute
90 Seconds
2 Minutes
3 Minutes
4 Minutes
Note: Cross zoning cannot be used in conjunction with APL.
Cross Zone 1
Disabled
Select “Cross Zone 1”. The System toggles between the following:
Disabled
Note: If Cross Zone Delay is enabled the system will display the zones that are programmed
with the following Zone Types: Day/Night, Interior Follower and perimeter.
Cross Zone 2
Disabled
Select “Cross Zone 2”. The System toggles between the following:
Disabled
Note: If Cross Zone Delay is enabled the system will display the zones that are programmed
with the following Zone Types: Day/Night, Interior Follower and perimeter.

Table of Contents

Other manuals for Honeywell L5200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell L5200 Series and is the answer not in the manual?

Honeywell L5200 Series Specifications

General IconGeneral
BrandHoneywell
ModelL5200 Series
CategorySecurity System
LanguageEnglish

Related product manuals