EasyManuals Logo
Home>Honeywell>Security System>L5200 Series

Honeywell L5200 Series Installation And Setup Guide

Honeywell L5200 Series
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
LYNX Touch Installation and Setup Guide
- 73 -
LYNX Touch (L5200CN/L7000CN) Canada Programming Default Values
Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4
Installer Code
4112 4112 4112 4112
System Type
RF Jam Disabled Disabled Disabled Disabled
Speaker Phone (L5200CN only) Disabled Disabled Disabled Disabled
Two Way Voice Disabled Disabled Disabled Disabled
RF House Code 0 0 0 0
Phone Notification (L5200CN only) Disabled Disabled Disabled Disabled
Remote Phone (L5200CN only) Enabled Enabled Enabled Enabled
Phone Detect Time (L5200CN only) 2 Minutes 2 Minutes 2 Minutes 2 Minutes
Events - Log All Press To Log All Log All Set Press To Log All Press To Log All
Events - Log Alarm Enabled Enabled Enabled Enabled
Events - Log Bypass Disabled Enabled Disabled Disabled
Events - Log Open/Close Disabled Enabled Disabled Disabled
Events - Log Trouble Enabled Enabled Enabled Enabled
Non Security Enabled Enabled Disabled Disabled
Remote Access Serial Disabled Disabled Disabled Disabled
Multi Mode Serial Disabled Disabled Disabled Disabled
Date Time
Calendar January 1, 2014 January 1, 2014 January 1, 2014 January 1, 2014
Enter Time 10:00AM 10:00AM 10:00AM 10:00AM
Time Zone Eastern (EST) Eastern (EST) Eastern (EST) Eastern (EST)
Day Light Savings time Yes Yes Yes Yes
Start Month March March March March
Start Week Second Second Second Second
End Month November November November November
End Week First First First First
Communicator
Communications Path None None None None
APL Disabled Disabled Disabled Disabled
City ID None None None None
CS ID None None None None
Sub ID None None None None
Supervision 24 Hours 24 Hours 24 Hours 24 Hours
Old Alarm Time 10 Minutes 10 Minutes 10 Minutes 10 Minutes
Remote Acc. Comm. Disabled Disabled Disabled Disabled
Multi Mode Comm. Disabled Disabled Disabled Disabled
GSM Fault Time 00 00 00 00
GSM Rollover No No No No
GSM 24 Hour Test No No No No
IP Fault Time 00 00 00 00
Use DHCP Yes Yes Yes Yes
NIC IP Address 255.255.255.255 255.255.255.255 255.255.255.255 255.255.255.255
Subnet Mask 255.255.255.255 255.255.255.255 255.255.255.255 255.255.255.255
Gateway IP Address 255.255.255.255 255.255.255.255 255.255.255.255 255.255.255.255
DNS Server IP Address 255.255.255.255 255.255.255.255 255.255.255.255 255.255.255.255
Zones
See Zone Programming Default Values
Reporter
Primary CS Info
Phone Type Contact Id: 4 Digit Contact Id: 4 Digit Contact Id: 4 Digit Contact Id: 4 Digit
Communicator Type None None None None
Phone Number Blank Blank Blank Blank
Account Number FFFF FFFF FFFF FFFF
Dynamic Priority None None None None
Dynamic Delay None None None None
Report All Press to Report All Press to Report All Press to Report All Press to Report All
Report Alarms Enabled Enabled Enabled Enabled
Report Troubles Enabled Enabled Enabled Enabled
Report Open/Close Disabled Disabled Disabled Disabled
Report Tests Enabled Enabled Enabled Enabled

Table of Contents

Other manuals for Honeywell L5200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell L5200 Series and is the answer not in the manual?

Honeywell L5200 Series Specifications

General IconGeneral
BrandHoneywell
ModelL5200 Series
CategorySecurity System
LanguageEnglish

Related product manuals