– 68 –
SYSTEM FUNCTIONS
Testing the System (to be conducted weekly)
Test Modes
The Test icon provides access to the Walk Test, Dialer Test, Communications Test and Reboot functions. The
Walk Test mode allows each protection point to be checked for proper operation. When the Walk Test mode is
active, the control sounds a single beep every 30 seconds as a reminder that the system is in the Test mode. The
Dialer Test performs a check of the system dialer. The Communications Test performs a check of the WiFi
and/or GSM communications. The Reboot feature allows you to reboot the system if required.
NOTE: An alarm message will not be sent to your alarm monitoring company during these tests.
Entering Test Mode
Disarm the system and close all protected windows, doors, etc. The “Ready” indicator should be lit.
Testing or Rebooting the System
Arm Away
Ready To Arm
Arm Stay
BackDelay
Settings
10:18 AM June 8, 2010
5200-100-033-V0
Tools
1. With the system in the disarmed state, select the “Tools” icon
from the second page of the Security Screen. The system
displays the Keypad screen.
Ready To Arm
Program the system
Enter Code:
Cancel
5200-100-035-V0
2 31
5
64
0
8
97
Clear
2. Enter your 4-digit Master User Code. The system displays the
Master User programming screen.
WiFi ConfigDate Time
Ready To Arm
Events
Back
Reminders
KeypadUsers
5200-100-036-V0
Slide Show
Test
3. Select the “Test” icon. The system displays the Test screen.