Honeywell
- 11 -
Figure 5-9 Planning Document Cabinet Protection
Note
The document cabinets as well as filing cabinets have thinner steel surfaces which act as a
membrane for acoustic (sound) waves. Therefore before leaving the installation check
carefully that too high sensitivity not is set.
Gates
For Gates and mainly Industrial Gates, which are made of steel, we recommend mounting the
detector on the upper part of the frame into which the vertical rods are welded.
A weather protection box (which can purchase from an electric wholesaler) should be used to
protect the detector from moisture. The detector shall be in direct metallic contact with the gate by
using screws or welded mounting plate.
Hatches and Chests
For protection of Hatches and Chests normally one detector is mounted inside the Hatch or Chest
door and one additional detector is mounted inside the chest cabinet if it consists of a solid
structure like concrete or steel.