8-42.
TROUBLESHOOTING.
CAUTION
THE
OPENING
OF
COVERS
OR
THE
REMOVAL
OF
PARTS,
EX-
CEPT
THOSE
TO
WHICH
ACCESS
CAN
BE
GAINED
BY
HAND,
IS
LIKELY
TO
EXPOSE
LIVE
PARTS.
IN
ADDITION,
ACCES-
SIBLE
TERMINALS
MAY
ALSO
BE
LIVE.
THE
APPARATUS
SHALL
BE
DISCONNECTED
FROM
ALL
VOLTAGE
SOURCES
BEFORE
ANY
ADJUSTMENT,
PARTS
REPLACEMENT,
OR
MAIN-
TENANCE
AND
REPAIR
ARE
PERFORMED
FOR
WHICH
THE
INSTRUMENT
MUST
BE
OPEN-
ED.
IF,
AFTERWARDS,
ANY
ADJUSTMENT,
MAINTENANCE
OR
REPAIR
OF
THE
OPENED
INSTRUMENT
UNDER
VOLT-
AGE
IS
REQUIRED,
IT
SHALL
BE
CARRIED
OUT
ONLY
BY
A
SKILLED
PERSON
WHO
IS
AWARE
OF
THE
HAZARD
IN-
VOLVED.
8-43.
When
4262A
is
inoperative
or
readings
for
the
sample
connected
to
the
UNKNOWN
terminals
are
incorrect,
you
should
first
check
power
line
voltage
used
and
next
the
behavior
of
instrument
with
respect
to
the
DUT
when
a
measurement
is
attempted.
The
two
may
be
incompatible.
In
addition,
check
for
appropriate
test
leads
or
fixture.
Determining
whether
the
trouble
is
in
an
external
device
connected
to
the
instrument
or
is
in
the
actual
instrument
is
primary
and
a
funda-
mental
procedure
which
must
precede
trouble-
shooting
the
LCR
Meter.
Occasionally,
the
un-
known
sample
may
have
characteristics
not
measurable
by
the
4262A.
Table
8-2
lists
the
examples
of
symptoms
likely
to
mislead.
You
should
also
be
concerned
about
the
operating
environmental
conditions
in
which
the
instrument
is
operated.
Surrounding
magnetic
fields
or
the
presence
of
a
strong
radiowave
will
sometimes
disturb
the
measurement.
To
isolate
any
instru-
ment
trouble
from
the
above
possibilities,
perform
the
following
examinations:
1)
Measure
a
sample
whose
characteristics
and
value
(L,
C
or
R
and
D/Q
value)
are
known
to
be
measurable
with
the
4262A.
Thus,
if
the
problem
is
restricted
to
difficulty
in
measuring
a
particular
sample,
it
might
suggest
that
the
sample
is
not
measurable
with
the
4262A.
8-16
Model
4262A
2)
Next,
connect
sample
directly
to
the
UN-
KNOWN
terminals
without
using
any
test
fixture
or
test
leads.
Any
external
equip-
ment
being
used
with
4262A
should
be
disconnected
from
the
connectors
of
the
4262A.
These
tests
isolate
troubles
on
the
external
equipment
or
test
jig
from
those
on
the
instrument.
3)
Securely
ground
the
instrument
to
earth.
If
environmental
conditions
are
suspected,
change
the
location
of
instrument.
4)
Use
a
four
terminal
connection
configura-
tion
and
measure
a
sample.
An
improper
connection
to
unknown
will
cause
a
meas-
urement
error.
5)
Properly
terminate
UNKNOWN
terminals
(short
or
open
circuit),
and
press
SELF
TEST
button.
Confirm
that
normal
PASS
annunciator
readouts
occur
on
the
LCR
DISPLAY.
8-44.
Figure
8-10,
“How
to
Use
Troubleshooting
Guides”,
is
helpful
when
starting
to
troubleshoot
the
4262A.
This
flow
diagram
shows
the
funda-
mental
procedures
which
breakdown
the
trouble
possiblilities
to
the
component
level.
The
trouble-
shooting
guides
are
divided
into
the
following
major
procedures:
Power
Supply
Section
Isolation
Procedure
(Fig.
8-17).
Basically
used
for
checking
internal
dc
power
supply
voltages
of
the
instrument:
The
guide
for
checking
the
power
supply
section
is
included
in
Figure
8-17.
Option
Section
Isolation
Procedure
(Fig.
8-17).
This
procedure,
which
is
used
to
isolate
the
option
section
from
the
overall
unit,
is
included
in
Figure
8-117.
If
the
instrument
is
a
standard
unit
equipped
with
no
option,
omit
this
procedure.
Analog
and
Digital
Section
Isolation
Procedure
(Fig.
8-17).
The
troubleshooting
guide
in
Figure
8-17
describes
how
to
distinguish
whether
the
faulty
assembly
is
located
in
the
analog
or
in
the
digital
section.
In
conjunction
with
the
troubleshooting
flow
diagram
of
Figure
8-17,
the
built-in
self
test
function
is
used
to
assist
in
isolating
the
analog
section
from
the
digital
section.
To
study
the
self
test
function,
refer
to
Figure
8-11.
-
'

Table of Contents

Other manuals for HP 4262A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 4262A and is the answer not in the manual?

HP 4262A Specifications

General IconGeneral
BrandHP
Model4262A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals