A-2
Specifications
Specifications
Environmental
1
If you are installing either the J8705A, J8707A, or J9289A modules, or any of the X2 transceivers,
the operating ambient temperature for the switch should not exceed 40C (104F).
Acoustic
5406 zl Switch and its bundles:
Geräuschemission LpA = 40.2 dB am fiktiven Arbeitsplatz nach
DIN 45635 T.19
Noise Emission LpA = 40.2 dB in a virtual workspace according to
DIN 45635 T.19
5412 zl Switch and its bundles:
Geräuschemission LpA = 45.8 dB am fiktiven Arbeitsplatz nach
DIN 45635 T.19
Noise Emission LpA = 45.8 dB in a virtual workspace according to
DIN 45635 T.19
Operating Non-Operating
Temperature: 0C to 55C (32F to 131F)
1
-40C to 70C (-40F to 158F)
Relative humidity:
(non-condensing)
15% to 80% at 55C (131F) 15% to 90% at 65C (149F)
Maximum altitude: 3.1 km (10,000 ft) 4.6 km (15,000 ft)