Fabric OS 6.2 administrator guide 309
Figure 39 HP StorageWorks B-Series iSCSI Director Blade ports
Enabling the iSCSI gateway service
The iSCSI gateway service translates and directs SCSI traffic between an iSCSI initiator and an FC target.
This procedure explains how to enable the iSCSI gateway service on the HP StorageWorks 4/256 SAN
Director.
1. Connect and log in to the switch.
2. Enter the fosConfig --show command to show the current Fabric OS configuration.
switch:admin> fosconfig --show
FC Routing service:disabled
iSCSI service:disabled
iSNS Client service: disabled
3. Enter the fosConfig --enable command to enable the iSCSI gateway service.
switch:admin> fosconfig --enable iscsi
iSCSI service is enabled
4. Verify that the iSCSI gateway service is enabled.
switch:admin> fosconfig --show
FC Routing service:disabled
iSCSI service:enabled
7
6
5
4
3
2
1
0
56-0000590-01 Rev A
!
FC4
16IP
ge7
ge6
ge5
ge4
ge3
ge2
ge1
ge0
GE
FC
scal e:
5/ 16" = 1"
ge7
ge0
G bE ports
F C ports
7
0
40. 1

Table of Contents

Other manuals for HP AE370A - Brocade 4Gb SAN Switch 4/12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP AE370A - Brocade 4Gb SAN Switch 4/12 and is the answer not in the manual?

HP AE370A - Brocade 4Gb SAN Switch 4/12 Specifications

General IconGeneral
BrandHP
ModelAE370A - Brocade 4Gb SAN Switch 4/12
CategorySwitch
LanguageEnglish

Related product manuals