4. Be sure to update the HP D2D software to the latest version. This is done from the Web
Management Interface (Settings/Software page), as described in the HP StorageWorks D2D
Backup System User Guide.
IMPORTANT: If your replacement flash stick is at a lower revision than the one it replaces,
you may experience a message of “Devices Starting” or “Initialising". This message will also
occur, if the D2D Backup System did not shutdown correctly. In this case, please wait a
minimum of 12 hours before updating software.
Figure 11 HP D2D 4112, HP D2D4004 or HP D2D4009 G1 flash memory module
Figure 12 HP D2D2500 G1 Series flash memory module
cable and USB connector to the memory module1
screw and bracket securing USB cable connector2
cable and connector to the motherboard3
flash memory module4
18 The flash memory module