cache module and BBWC). The P411 cards are installed in PCI-e Slots 5 and 6. Part numbers
for the P411 card are as follows:
HP Smart Array P411/512 MB with BBWC Controller: 462832-B21
512 MB memory: 462975-001
BBWC: 462976-001
For more information about the HP Smart Array cards, search on http://www.hp.com/support/
manuals.
The configuration of the system memory is 96 GB (12 x 8 GB DIMMs, 6 per processor). The
part number for each 8 GB DIMM is 500662-B21.
The system has an HP StorageWorks 8Gb Dual Channel PCI-e to Fibre Channel Host Bus
Adapter, part number AJ764A.
The system has an HP NC550SFP Dual Port 10GbE Server Adapter, part number 581201-B21.
The system has an HP SAS Expander Card, part number 468406-B21, in PCI-e Slot 1.
Figure 2 Rear view of the HP D2D4312
5. Fibre Channel card1. Power supplies (two)
6. RAID cards2. iLO2 Management port (do not use for data)
7. HP SAS expander card3. LAN ports 3 (required connection) and 4
4. 10–Gb Ethernet card with two ports
Using the ProLiant Guide with HP D2D4106/4112 G2 models
When using the HP ProLiant DL180se G6 guide, be aware of the following HP D2D-specific
information:
The CPU is Intel Xeon X5550 (Spare P/N 490070-001) there are two per system
The HP D2D has 12 removable hard disks. The 12th disk is an online spare disk. If one of
the other disks fails, the online spare disk immediately takes its place. (The HP D2D4106 has
12 x 500 GB hard disks; the HP D2D4112 has 12 x 1 TB hard disks.)
The configuration of the system memory is 72 GB (9 x 8 GB DIMMs; 5 for the first processor,
4 for the second). The part number for each 8 GB DIMM is 500662-B21.
The HP D2D is supplied with an HP Smart Array P212/Zero Memory Controller (with 512
MB and BBWC) pre-installed in one of the full-height PCI-e slots. For more information about
this card, search on http://www.hp.com/support/manuals. Part numbers are as follows:
HP Smart Array P212/Zero Memory Controller: 462828-B21
512MB BBWC -Cache and BBWC: 462967-B21
8 Introduction

Table of Contents

Other manuals for HP D2D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP D2D and is the answer not in the manual?

HP D2D Specifications

General IconGeneral
BrandHP
ModelD2D
CategoryStorage
LanguageEnglish

Related product manuals