Control panel message Description Recommended action
RTC (real-time clock) battery may need to
be replaced.
problem persists, replace the RTC battery. See
the Removal and Replacement section for
instructions on installing a new battery.
008–Microcode Patch Error Processor is not supported by the BIOS. 1. Upgrade BIOS to proper version.
2. Change the processor.
009–PMM Allocation Error during MEBx
Download
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory conguration was recently
changed, unplug the computer, restore
the original memory conguration, and
reboot the computer.
4. If the error persists, replace the system
board.
00A-Product Information Not Valid The product information programmed into the
system board is missing or invalid.
Use Computer Setup to update this information.
00B-MEBx Module did not checksum correctly Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory conguration was recently
changed, unplug the power cord, restore
the original memory conguration, and
reboot the computer.
4. If the error persists, replace the system
board.
00C-PMM Deallocation Error during MEBx
Cleanup
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory conguration was recently
changed, unplug the power cord, restore
the original memory conguration, and
reboot the computer.
4. If the error persists, replace the system
board.
00D-Setup Error during MEBx Execution MEBx selection or exit resulted in a setup
failure.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory conguration was recently
changed, unplug the power cord, restore
the original memory conguration, and
reboot the computer.
4. If the error persists, replace the system
board.
POST numeric codes and text messages 93

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProDesk 400 G3 Small Form Factor and is the answer not in the manual?

HP ProDesk 400 G3 Small Form Factor Specifications

General IconGeneral
BrandHP
ModelProDesk 400 G3 Small Form Factor
CategoryDesktop
LanguageEnglish

Related product manuals