Setting Station Run Times
1. Turn the dial to the RUN TIMES position.
2. The display will show the last program selected (A, B, or
C) and the station number selected. The run time for that
station will ash. You can switch to another program by
pressing the PRG button.
3. Use the + and - buttons to change the station run time on
the display. You may set station run times from 1 minute
to 6 hours.
4. Press the → button to advance to the next station.
5. Repeat steps 2 and 3 for each station.
Run Times in Seconds Mode
Users can enable a Seconds Mode to input Station Run
Times with seconds resolution. To select Seconds Mode:
1. With the dial set to Run, hold the + button while turning
the dial to Start Times, then release the + button.
2. Press the + and - buttons to enable/disable Seconds
Mode. The pointer indicator on the display will select SEC
(for seconds) or HH:MM (for standard run times).
3. With the Seconds Mode enabled, turn the dial to the
Run Times position and use the + and - buttons to
increase and decrease run times for each station in
1-second intervals.
4. Users can set Run Times with seconds resolution up to
5 minutes. Any Run Time longer than 5 minutes will be
set in 1-minute increments.