Operating Specications
• Station Count: Conventional wiring from 4 to 23 stations,
two-wire EZ Decoder System option up to 32 stations
• Station Run Time: 1 minute to 6 hours (optional Seconds
Mode, see pg. 18)
• Start Times: 4 individual starts per program, three
programs available (A, B, C)
• Watering Schedule: 7-day calendar, interval watering up
to a 31-day interval or true odd or even day programming
Electrical Specications
• Transformer Input: 120 VAC, 60 Hz (230 VAC, 50/60 Hz
for international use)
• Transformer Output: 24 VAC, 1 A
• Station Output: 24 VAC, 0.56 A per station
• P/MV Output: 24 VAC, 0.28 A
• Maximum Output: 24 VAC, 0.84 A (includes Master
Valve Circuit)
• Battery: 9 V alkaline battery (not included) used only for
non-AC programming of the control panel
• Battery, front panel, internal CR2032 lithium for real-
time clock
Specications
Cabinet Dimensions
• Height: 9" (23 cm)
Width: 10" (21.5 cm)
Depth: 4⁄" (10.9 cm)
• Cabinet is NEMA 3R, IP44 rated
Default Settings
All stations are set to zero run time. This controller has a
non-volatile memory that retains all entered program data,
even during power outages, without need for a battery.