ADVAnCED FEATUREs
Programmable Sensor Override
The XC allows the user to program the controller so that the sensor
disables watering on only desired stations. For example, patio gardens
that have pots under overhangs and roofs may not receive water when it
rains and will continue to need to be watered during periods of rain.
To program sensor override:
1. Turn the dial to the RUN position.
2. Press and hold the button down while turning the
dial to START TIMES position.
3. Release the button. At this point, the display
will show the station number, ON, and the icon,
will be flashing.
4.
Press the
or
button to enable or disable the
sensor for the station sho
wn.
ON = Sensor enabled (will suspend irrigation)
OFF= Sensor disabled (will allow watering)
6. Use the or buttons to scroll to the next station that you would like
to program the sensor override.
When the XC receives an input from the sensor to
disable watering, the display will indicate those
stations that have been programmed to override the
sensor. A station that is running in the sensor override mode will flash
the
and icons alternately.
Test Program of All Stations
The XC allows the user a simplified method for running a test pro-
gram. This feature will operate each station in numerical sequence,
from the lowest to the highest.
1. With the dial in the RUN position, press and hold thebutton. The
station number will be displayed and the time will be flashing.
2. Use the or
buttons to set the run time from 1 to 15 minutes. The run time needs to be entered only once.
3. After a 2 second pause, the test program will start.
Hunter Quick Check
Diagnostics
This feature allows you to quickly diagnose wiring problems with your
controller. Instead of having to check each field wiring circuit for
potential problems, you can use the Hunter Quick Check circuit test
procedure. To initiate the Quick Check test procedure:
1. Press the , , , andbuttons simultaneously. In the stand-
by mode, the LCD will display all segments.
2. Press thebutton once to begin the Quick Check procedure. Within
seconds, the system searches all stations for detecting any circuit
problems. When a field wiring short is detected, an ERR symbol
preceded by the station number will momentarily flash on the
display. After the Quick Check completes running the circuit
diagnostic procedure, the controller returns to the automatic
watering mode.
NOTE: The controller default is for the sensor to disable
watering on all zones when rain occurs.