HyPrecision Predictive waterjet pump Operator Manual 810120 221
9 – Installation
Installation
Stop-procedure Timers
The pump is idle when the intensifier stops stroking.
Stop After Idle
When this feature is on, the pump turns off after the idle duration timer expires.
Cooling After Idle
When this feature is on, the pump goes into cooling mode after the idle duration timer expires.
Idle Duration
This timer determines how long the pump is idle before it turns off or goes into cooling mode.
The default is 10 minutes.
Stop Boost Pump
This timer determines how long the pump is idle before the boost pump turns off. This applies
to internal and external boost pumps.
The default is 180 seconds.
LP Drain Valve
This timer determines how long after the pump turns off the low-pressure (LP) drain valve
opens and releases the low-pressure water from the system.
The default is 30 seconds.