APPENDIX E
e-2 HySpeed HT2000 Instruction Manual
19
General
This appendix will enable a qualified electrician to install the power cable to the EMI filter on all CE
220/380/415 volt power supplies (073198, 073199).
Power Cable
The power cable is customer supplied. See Power Cable on pages 3-5 and 3-6 for recommended cable
sizes. Final specification and installation of the power cord should be made by a licensed electrician and
according to applicable national or local codes. See also Mains Supply on page e-2 for further power (supply)
cable shielding recommendations.
Connect Power Cable
Connect one end of the power cable to the EMI filter first and then connect the other end to the line
disconnect switch.
Power Supply
1. Locate the EMI filter on the top rear of the power supply (see Figure e-1).
Figure e-1 Power Supply with EMI Filter – Side View
EMI Filter
Strain Relief
HySpeed HT2000