MAINTENANCE
1
powermax1000 Service Manual 3-11
Schematic for building an IGBT tester
Troubleshoot the Hypertherm IGBT tester
1. Inspect the leads and the IGBT tester for damage.
2. Verify that the battery voltage is greater than 8V.
3
. Test the IGBT Tester, itself, as shown below. If the results do not match the table, replace the lead connections.
Connect leads Short test Open test
None Pass Fail
Red to Black Fail Pass
Legend
1. Collector 1 (C1)
2. Emitter 2 (E2)
3. Collector 2, Emitter 1 (C2,E1)
4. Gate 1 (G1)
5. Emitter 1 (E1)
6. Emitter 2 (E2)
7. Gate 2 (G2)
9 VDC
battery
R4
2.0K
009036
N.O.
pushbutton
switch
Y
ellow
Minigrabber
test clip 4
5
Black
Minigrabber
test clip
R1
3.01M
009464
3
7
6
2
1
D1
Red LED lamp
109092
Red Minigrabber
test clip
R3
2.0K
009036
Q1
150A
1400V
109125

Table of Contents

Other manuals for Hypertherm powermax1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm powermax1000 and is the answer not in the manual?

Hypertherm powermax1000 Specifications

General IconGeneral
BrandHypertherm
Modelpowermax1000
CategoryWelding System
LanguageEnglish

Related product manuals