SETUP
3-8 powermax30 Operator Manual
Gas supply
Powermax30
Water and particle filter
Oil filter Oil vapor filter
Additional gas filtration
When site conditions introduce moisture, oil or other contaminants into the gas line, use a three-
stage coalescing filtration system, such as the Eliminizer filter kit (part number 128647) available
from Hypertherm distributors. A three-stage filtering system works as shown below to clean
contaminants from the gas supply.
The filtering system should be installed between the 1/4 NPT quick-disconnect coupler and the
power supply.