MAINTENANCE AND PARTS
2
5-20 powermax30 Operator Manual
6. Unscrew the element from the filter body while being careful not to allow the element to rotate.
7. Screw the new element to the filter body.
8. Reattach the filter bowl.
9. Reposition the air filter assembly in the bracket and replace its retainer nut.
10. Reconnect the gas supply to check for leaks.
11. Slide the cover back onto the power supply. Position the handle over the holes in the top of
the cover, then use the 2 screws to secure the cover.
12. Reconnect the electrical power and the gas supply.
Replacement and accessory parts
The following sections list part numbers and quantities needed for common replacement parts for
the Powermax30.
Power cords and adapters
Part number Description Quantity
228142 Kit: Powermax30 CSA power cord and adapters 1
229135 Powermax30 CSA power cord 1
229132 Extension power cord subassembly: 120V/15A adapter 1
229133 Extension power cord subassembly: 240V/20A adapter 1
229134 Extension power cord subassembly: 120V/20A adapter 1
228140 Kit: Powermax30 CE power cord 1
Accessory parts
Part number Description
127102 Basic plasma cutting guide
027668 Deluxe plasma cutting guide
127144 Dust cover
127170 Carrying case
127217 Carry strap
128647 Air filtration kit
PMX30_OM_05.qxp:PMX30_OM_05 10/7/09 12:46 PM Page 5-20