3174
Model91R
3174 Model 82R
The 3174 Model
91
R
is
a
small-cluster
controller
designed
for
remote operations. It
contains a Type 1 Communication
Adapter
that provides EIA 232D/CCITI V.24 and
CCITT V.35 interfaces
for
SNA/SDLC, BSC,
or
X.25 remote
link
attachment. It has
2MB of base storage and one 5-1/4-inch, 2.4MB, high
..
capacity diskette drive. A
four-port
terminal
adapter supports
four
terminals
directly
or
eight 3270
terminals
through an IBM 3299
Terminal
Multiplexer.
Customizing
is
performed
with a control unit
terminal
attached
to
port 0 of the 3174.
Any
terminal
can be attached to port 0 at
other
times. The Model
91
R supports full
keyboard utilities.
Subsystem
online
tests and problem
determination
are
performed through a
control unit
terminal
attached to any port
or
multiplexer
without
interrupting
other
terminals
attached
to
the 3174. Offline tests
are
performed through the 3174
control panel.
The
91
R
controller
supports no customer-installable features.
The 3174 Model 82R is a
small-cluster
controller
designed
for
remote operations. It
contains a Type 2 Communication
Adapter
that provides an
X.21
interface
(CCITI
V.11)
for
SNA/SDLC
or
X.25 remote
link
attachment. It has 1 MB of base storage
and one 5-1/4-inch, 1.2MB, high-capacity diskette drive. A four-port
terminal
adapter supports
four
terminals
directly
or
eight 3270
terminals
through IBM 3299
Terminal Multiplexers.
Customizing is performed with a control unit
terminal
attached to port 0 of the 3174.
Any terminal can be attached to port
0 at
other
times. The 82R supports full
keyboard utilities.
Subsystem
online
tests and problem
determination
are
performed through a
control
unit
terminal
attached to any port
or
multiplexer
without
interrupting
other
terminals
attached to the 3174. Offline tests
are
performed through the 3174
control panel.
This model of the 3174
controller
does not
support
any customer-installable
features.
3-12 IBM 3270 Information Display System 3174
Establishment
Controller
Introduction

Table of Contents

Other manuals for IBM 3174

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 3174 and is the answer not in the manual?

IBM 3174 Specifications

General IconGeneral
BrandIBM
Model3174
CategoryController
LanguageEnglish

Related product manuals