3174 Model 92R
The
3174
Model
92R
is a small-cluster controller designed for remote operations. It
contains a Type 2 Communication Adapter that provides an
X.21
interface (CCITT
V.11) for SNA/SDLC
or
X.25 remote
link
attachment. It has 2MB of base storage
and one 5-1/4-inch, 2.4MB, high-capacity diskette drive. A four-port terminal
adapter supports four terminals directly
or
eight
3270
terminals through IBM 3299
Terminal Multiplexers.
Customizing is performed with a control unit terminal attached to port
0 of the
3174.
Any terminal can
be
attached to port 0 at other times. The
92R
supports full
keyboard utilities.
Subsystem online tests and problem determination are performed through a
control unit terminal attached to any port
or
multiplexer without interrupting other
terminals attached to the
3174.
Offline tests are performed through the 3174
control panel.
The
3174
Model
92R
does not support any customer-installable features.
Chapter
3.
Models of the 3174 Establishment
Controller
3-13

Table of Contents

Other manuals for IBM 3174

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 3174 and is the answer not in the manual?

IBM 3174 Specifications

General IconGeneral
BrandIBM
Model3174
CategoryController
LanguageEnglish

Related product manuals