Table 27. T&D Error Messages and Action (continued)
Error Message Description Action
TD 5 FRU 1 X Operator Panel Failure 1. This error can occur if a key is not
pressed in less than 10 seconds.
Run T&D05 again to verify the
problem.
2. Replace the operator panel.
See “Operator Panel” on page 355.
3. Replace the logic board.
See “Logic Board - Model A00” on
page 370.
4. Replace the operator panel cable.
TD 6 FRU 0 X (*) Parallel Interface
Failure
Replace the logic board.
See “Logic Board - Model A00” on
page 370.
TD 8 FRU 0 X Microcode Error Replace the logic board.
See “Logic Board - Model A00” on
page 370.
TD 9 FRU 0 X (*) Serial Attachment
Failure
1. Replace the logic board.
See “Logic Board - Model A00” on
page 370.
2. Replace the serial attachment card.
See “Serial Attachment Card -
Model A00” on page 390.
TD 10 FRU 0 1 (*) ASF/Stacker Failure 1. Replace the logic board.
See “Logic Board - Model A00” on
page 370.
2. Replace the stacker cable
assembly.
Chapter 2. Diagnostics