Optional-device problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 8864,” on page 23 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only)”, that step must be performed only by a
trained service technician.
Symptom Action
An IBM optional device that was
just installed does not work.
1. Make sure that:
v The device is designed for the server (see the ServerProven
®
list on the
World Wide Web at http://www.ibm.com/servers/eserver/serverproven/
compat/us/).
v You followed the installation instructions that came with the device.
v The device is installed correctly.
v You have not loosened any other installed devices or cables.
v You updated the configuration information in the Configuration/Setup Utility
program. Whenever memory or any other device is changed, you must
update the configuration.
2.
Reseat the device that you just installed.
3. Replace the device that you just installed.
An IBM optional device that
used to work does not work
now.
1. Make sure that all of the hardware and cable connections for the device are
secure.
2. Make sure the memory is enabled in the Configuration/Setup Utility program.
See, “Memory problems” on page 93.
3. If the device comes with test instructions, use those instructions to test the
device.
4. If the failing device is a SCSI device, make sure that:
v The cables for all external SCSI devices are connected correctly.
v The last device in each SCSI chain, or the end of the SCSI cable, is
terminated correctly.
v Any external SCSI device is turned on. You must turn on an external SCSI
device before turning on the server.
5.
Reseat the failing device.
6. Replace the failing device.
POST reporting PCI Event:
Redundant PCI Host Bridge IB
Link Failed. Slot Number = NA.
Bus Number = NA.Device ID =
0xffff. Vendor ID = 0xffff
1. Check for bent pins between the Microprocessor board and the PCI board.
2. PCI board assembly.
3. Microprocessor tray assembly.
Chapter 5. Diagnostics 97

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 88643RU - System x3850 - 8864 and is the answer not in the manual?

IBM 88643RU - System x3850 - 8864 Specifications

General IconGeneral
BrandIBM
Model88643RU - System x3850 - 8864
CategoryServer
LanguageEnglish

Related product manuals