v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 8864,” on page 23 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only)”, that step must be performed only by a
trained service technician.
Error message Action
Unknown SERR/PERR detected on PCI bus
Chassis#=X Slot#=Y Bus#=Z Dev.ID=0xSSSS
Vend.ID=0xTTTT Status=0xUUUU
DevFun#=0xVV
1. If the slot number is greater than 0, complete the following
steps:
a. Reseat the adapter.
b. Replace the adapter.
2.
If the slot number is 0, replace the PCI board.
Address of special cycle DPE on PCI primary
Chassis#=X Slot#=Y Bus#=Z Dev.ID=0xSSSS
Vend.ID=0xTTTT Status=0xUUUU
DevFun#=0xVV
1. If the slot number is greater than 0, complete the following
steps:
a. Reseat the adapter.
b. Replace the adapter.
2.
If the slot number is 0, replace the PCI board.
Master read parity error on PCI primary
Chassis#=4 Slot#=2 Bus#=3 Dev.ID=0xaa99
Vend.ID=0xccbb Status=0xeedd DevFun#=0xff
1. If the slot number is greater than 0, complete the following
steps:
a. Reseat the adapter.
b. Replace the adapter.
2.
If the slot number is 0, replace the PCI board.
Received target parity error on PCI primary
Chassis#=X Slot#=Y Bus#=Z Dev.ID=0xSSSS
Vend.ID=0xTTTT Status=0xUUUU
DevFun#=0xVV
1. If the slot number is greater than 0, complete the following
steps:
a. Reseat the adapter.
b. Replace the adapter.
2.
If the slot number is 0, replace the PCI board.
Master write parity error on PCI primary
Chassis#=X Slot#=Y Bus#=Z Dev.ID=0xSSSS
Vend.ID=0xTTTT Status=0xUUUU
DevFun#=0xVV
1. If the slot number is greater than 0, complete the following
steps:
a. Reseat the adapter.
b. Replace the adapter.
2.
If the slot number is 0, replace the PCI board.
Device signaled SERR on PCI primary.
Chassis#=X Slot#=Y Bus#=Z Dev.ID=0xSSSS
Vend.ID=0xTTTT Status=0xUUUU
DevFun#=0xVV
1. If the slot number is greater than 0, complete the following
steps:
a. Reseat the adapter.
b. Replace the adapter.
2.
If the slot number is 0, replace the PCI board.
Slave signaled parity error on PCI primary
Chassis#=X Slot#=Y Bus#=Z Dev.ID=0xSSSS
Vend.ID=0xTTTT Status=0xUUUU
DevFun#=0xVV
1. If the slot number is greater than 0, complete the following
steps:
a. Reseat the adapter.
b. Replace the adapter.
2.
If the slot number is 0, replace the PCI board.
Signaled target abort on PCI primary
Chassis#=X Slot#=Y Bus#=Z Dev.ID=0xSSSS
Vend.ID=0xTTTT Status=0xUUUU
DevFun#=0xVV
1. If the slot number is greater than 0, complete the following
steps:
a. Reseat the adapter.
b. Replace the adapter.
2.
If the slot number is 0, replace the PCI board.
144 IBM System x3850 Type 8864: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 88643RU - System x3850 - 8864 and is the answer not in the manual?

IBM 88643RU - System x3850 - 8864 Specifications

General IconGeneral
BrandIBM
Model88643RU - System x3850 - 8864
CategoryServer
LanguageEnglish

Related product manuals