79
Updated
28/02/01
Netfinity 7600 Power, Monitors, Accessories
Part Number Description Part Number Description
Power
1,9
Conversion Kits
33L37xx
10
250 W Hot-Swap Redundant Power Supply
9
37L6860 8Ux24D Rack-to-Tower Kit
1
94G7448 Rack Power Cable Type C12 (3.7m, 12 ft.)
9
Rack and NetBAY
2,10
Uninterruptable Power Supply (UPS)
2
930842P Netfinity Enterprise Rack
SUP102Y APC Smart-UPS 1000 930842X Netfinity Enterprise Expansion Cabinet
SUP142Y APC Smart-UPS 1400 9306900 Netfinity Rack
14RIxxx
12
APC Smart-UPS 1400RMB
3
9306910 Netfinity Rack (includes perforated door)
30RIxxx
12
APC Smart-UPS 3000RMB
3
9306200 Netfinity NetBAY22
37L6862 APC Smart-UPS 5000RMB
4
10L6912 Netfinity NetBAY3
3
Monitors
5
37L6888
Netfinity Flat Panel Monitor Rack Mount Kit
T3347xx
11
E51 Color Monitor 15” (350-mm, 13.8” Viewable Image
Size), stealth black
6
94G7448 Rack Power Cable Type C12 (3.7m)
10
T31U2xx
11
E54 Color Monitor 15” (350-mm, 13.8” Viewable Image
Size), stealth black
6
Keyboard and Mouse
4
T32U3xx
11
E74 Color Monitor 17” (403-mm, 15.9” Viewable Image
Size), stealth black
6
28L36xx
8
Space Saver II Keyboard
5, 7
T274Axx
11
G78 Color Monitor 17” (454-mm, 17.9” Viewable Image
Size), stealth black
6
28L36xx
9
Preferred Keyboard (stealth black)
6
11AG1xx
11
T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0”
Viewable), stealth black
7
28L3675 Sleek 2-Button Stealth Black Mouse
1. Netfinity 7600 includes three 250W hot-swap redundant power supplies, with the ability to
accept one additional 250 W Hot-Swap Redundant Power Supply P/N 33L37xx. To assist in
determining when an additional power supply is required to preserve redundancy, a “Non-
Redundant LED” is a standard feature of the Netfinity 7600. Predicting whether or not a
particular configuration will require an additional power supply for redundancy is very
complex. However, once the system is installed, the“Non-Redundant LED” will indicate when
an additional power supply is required. The following sample configuration is provided as a
reference.
1. Includes one Netfinity NetBAY3 with casters.
2. Netfinity 7600 rack models are housed in a 19” rack mountable drawer and require one of the racks listed
here. See IBM Netfinity Rack Cabinet and Options section for IBM rack supported devices.
3. Netfinity 7600 requires 8Ux24D Rack-to-Tower Kit (P/N 37L6860) for use with a NetBAY3. A maximum
of three NetBAY3 enclosures, including the one which ships with the conversion kit, may be stacked beneath
a supported Netfinity tower server. Optional NetBAY3s must be shipped separately and not while attached to
the base configuration. See IBM Netfinity NetBAY3 Stackable Enclosure section for supported devices.
4. Netfinity 7600 ships without a keyboard or mouse.
5. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).
6. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a
keyboard tray with a flat panel display.
7. Advanced TrackPoint IV features are not available on IBM Netfinity systems.
8. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian,
50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland, 19K3832=Sweden/Finland,
19K3833=Portugal, 19L3834=Belgium, 19K3836=Russia, 19K3837=Poland.
9. Where ‘xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English,
31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.
10. The Netfinity 7600 ships with a standard country power cord. For connection of a Rack model to a high
voltage UPS or PDU, a Rack Power Cable P/N 94G7448 (type C12 - one for each power supply), must be
ordered.
2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.
3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.
4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.
5. Netfinity 7600 uses an SVGA controller (S3 Trio 3D chipset) with 4 MB of video memory.
6. Installation within a rack requires optional Monitor Compartment P/N 94G7444.
7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit
P/N 37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may
coexist within the same keyboard tray.
8. The addition of a DLT tape drive may require a 4th power supply to preserve redundancy.
9. Rack Power Cable P/N 94G7448 (type C12 - one for each Power Supply), must be ordered
for power connection to a high voltage UPS or PDU.
10. Where ‘xx’ refers to a country specific code: 60=Saudi Arabia, 61=Europe, 62=Denmark,
63=Israel, 64=Italy, 65=South Africa, 66=Switzerland, 67=United Kingdom&Arabia.
11. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy,
SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.
12. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark,
ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland,
UKM=United Kingdom, EUR=Europe.
Slot 1- Bus A- 66 MHz- 3.3 V or Universal
Slot 6- Bus B- 33 MHz- 5 V or Universal, Active PCI
Slot 2- Bus A- 66 MHz- 3.3 V or Universal
Slot 5- Bus B- 33 MHz- 5 V or Universal, Active PCI
Slot 4- Bus B- 33 MHz- 5 V or Universal, Active PCI
Slot 3- Bus B- 33 MHz- 5 V or Universal, Active PCI
RAID Adapter
All Slots- Full Length, 64-bit
Number of Power
Supplies
System Configuration Supported
Typical Redundant Configuration
4 x Processors
3
8
6 x PCI Adapters
7 x Half-High or 10 Slim-Line HDDs
16 x 512 MB RDIMMs
4 Full Configuration with Redundancy