11. Reconnect external cables and power cords.
Thermal grease
The thermal grease must be replaced whenever the heat sink has been removed
from the top of the microprocessor and is going to be reused or when debris is
found in the grease.
To replace damaged or contaminated thermal grease on the microprocessor and
heat sink, complete the following steps:
1. Place the heat sink on a clean work surface.
2. Remove the cleaning pad from its package and unfold it completely.
3. Use the cleaning pad to wipe the thermal grease from the bottom of the heat
sink.
Note: Make sure that all of the thermal grease is removed.
4. Use a clean area of the cleaning pad to wipe the thermal grease from the
microprocessor; then, dispose of the cleaning pad after all of the thermal grease
is removed.
Microprocessor
0.02 mL of thermal
grease
5. Use the thermal-grease syringe to place 9 uniformly spaced dots of 0.02 mL
each on the top of the microprocessor. The outer-most dots must be within
approximately 5 mm of the edge. This is to ensure uniform distribution.
Note: 0.01 mL is one tick mark on the syringe. If the grease is properly applied,
approximately half (0.22 mL) of the grease will remain in the syringe.
6. Install the heat sink onto the microprocessor as described in “Removing and
installing a microprocessor” on page 91.
Chapter 4. Removing and replacing server components 93

Table of Contents

Other manuals for IBM System x3500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3500 and is the answer not in the manual?

IBM System x3500 Specifications

General IconGeneral
BrandIBM
ModelSystem x3500
CategoryServer
LanguageEnglish

Related product manuals