408-900-000 MLNX:MLNX_DiagnosticTestEthernetPort Test Failed
Explanation: Port Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Make sure that the physical link of the port under test in the active state.
2. If these condition was met but the test keeps failing the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.
408-901-000 MLNX:MLNX_DiagnosticTestIBPort Test Failed
Explanation: Port Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Make sure that the physical link of the port under test in the active state and a subnet manager running on the
fabric to which the port is attached.
2. If these condition was met but the test keeps failing the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.
DSA memory isolation test results
The following messages can result when you run the memory isolation test.
201-000-000 Standalone Memory Test Passed
Explanation: Quick/Full Memory Test All CPUs Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
408-900-000 201-000-000
710
IBM System x3550 M4 Type 7914: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M4 and is the answer not in the manual?

IBM System x3550 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3550 M4
CategoryServer
LanguageEnglish

Related product manuals