4 - 1
4-1 PREPARATION
Some adjustments must be performed on the ADJUSTMENT MODE. CS-FR3000 CLONING SOFTWARE, OPC-478 CLONING
CABLE, OPC-592 ADAPTOR CABLE are required when enter the adjustment mode. Refer to the next page in detail.
REQUIRED TEST EQUIPMENT
SECTION 4 ADJUSTMENT PROCEDURES
EQUIPMENT
DC power supply
RF power meter
(terminated type)
Frequency counter
FM deviation meter
GRADE AND RANGE
Output voltage : 13.6 V DC [FR4000]
13.2 V DC [FR4100]
Current capacity : 25 A or more
Measuring range : 1100 W
Frequency range : 300600 MHz
Impedance : 50
SWR : Less than 1.2 : 1
Frequency range : 0.1600 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity : 100 mV or better
Frequency range : DC600 MHz
Measuring range : 0 to ±5 kHz
EQUIPMENT
Audio generator
Attenuator
Standard signal
generator (SSG)
AC millivoltmeter
Oscilloscope
Digital multimeter
GRADE AND RANGE
Frequency range : 3003000 Hz
Output level : 1500 mV
Power attenuation : 40 or 50 dB
Capacity : 100 W or more
Frequency range : 120600 MHz
Output level : 0.1 µV32 mV
(127 to 17 dBm)
Measuring range : 10 mV10 V
Frequency range : DC20 MHz
Measuring range : 0.0120 V
Input impedance : 10 M/V DC or better