14
Installation and Servicing
SECTION 1 - GENERAL
1.16 BOILER DIMENSIONS, SERVICES & CLEARANCES
all dimensions in mm
The boiler connections are made on the boiler connection tails.
Refer to Section 2.15.
The following minimum clearances must be maintained for
operation and servicing.
Additional space will be required for installation, depending upon
site conditions.
Side and Rear Flue
a. Provided that the ue hole is cut accurately, e.g. with a core
drill, the ue can be installed from inside the building where
wall thicknesses do not exceed 600mm. Where the space
into which the boiler is going to be installed is less than
the length of ue required the ue must be tted from the
outside.
*Bottom clearance
Bottom clearance after installation can be reduced to 5mm.
This must be obtained with an easily removable panel to provide
the 100mm clearance required for servicing.
Front clearance
The minimum front clearance when built in to a cupboard is 5mm
from the cupboard door but 450mm overall clearance is still
required, with the cupboard door open, to allow for servicing.
Rear Flue Only
Minimum top clearance required is 145mm.
395 278
76
826
Side flue
dim. A
2.5 from case
Underside View - Pipe Dimensions to Wall
43 65 28 30 60 75 56 38
CH Flow
Data Plate
DHW Outlet
Gas Inlet
Condensate
DHW Inlet
PRV
CH Return
Connections
extensions
Front clearance
The minimum front clearance when built in to a
cupboard is 5mm from the cupboard door but
450mm overall clearance is still required, with the
cupboard door open, to allow for servicing.
* Bottom clearance
Bottom clearance after installation can be
reduced to 5mm. This must be obtained with
an easily removable panel to provide the
100mm clearance required for servicing.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL Logic Plus Combi C 24 and is the answer not in the manual?

IDEAL Logic Plus Combi C 24 Specifications

General IconGeneral
BrandIDEAL
ModelLogic Plus Combi C 24
CategoryBoiler
LanguageEnglish

Related product manuals