8
Installation and Servicing
SECTION 1 - GENERAL
Table 1 - General Data
Note. Gas consumption is calculated using a
caloric value of 38.7 MJ/m
3
(1038 Btu/ft
3
) gross
or 34.9 MJ/m
3
(935 Btu/ft
3
) nett.
To obtain the gas consumption at a different
caloric value:
a. For l/s - divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
3
)
b. For Btu/h - multiply the gross heat input (kW)
by 26.8
c. For ft
3
/h - divide the gross heat input (Btu/h)
by the gross C.V. of the gas (Btu/ft
3
)
d. For m
3
/h - multiply l/s by 36
Key to symbols
GB = United Kingdom IE = Ireland (Countries of destination)
PMS = Maximum operating pressure of water
C
13
C
33
C
53
= A room sealed appliance designed for connection via ducts to a
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orices which, in this case, are concentric. The fan is up stream of
the combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas, Group H only.
* The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certied by a notied body.
26 33 38
Gas supply 2H - G20 - 20mbar
Gas Supply Connection 15mm copper compression
Injector Size mm 4.15 4.65 4.9
Inlet Connection DHW 15mm copper compression
Outlet Connection DHW 15mm copper compression
Flow Connection Central Heating 22mm copper compression
Return Connection Central Heating 22mm copper compression
Flue Terminal Diameter mm 100
Average Flue Temp-Mass Flow Rate (DHW) 30ºC 11g/s 32ºC 13g/s 35ºC 15g/s
Average Flue Temp-Mass Flow Rate (CH) 63ºC 11g/s 68ºC 13g/s 73ºC 13g/s
Maximum Working Pressure (Sealed Systems) bar 2.5
Maximum Domestic Hot Water Inlet Pressure bar 10.0
Minimum Domestic Hot Water Inlet Pressure* bar 1.1 1.6 1.9
Electrical Supply 230 V ~ 50 Hz.
Power Consumption W 86 93 93
Fuse Rating External : 3A Internal : T4A HRC L250 V
Water content CH litre 1.2
DHW litre 1.0
Packaged Weight kg 38.05 38.15 38.35
Maximum Installation Weight kg 32.65 32.75 32.95
Boiler Casing Size Height mm 826
Width mm 395
Depth mm 278
*Required for maximum ow rate. Boiler operates down to 2 l/min DHW delivery
** In areas of low water pressure the DHW restrictor can be removed
Maximum DHW Input : 26 33 38
Nett CV kW 24.3 30.4 35.4
Gross CV kW 27.0 33.7 39.3
Gas Consumption m
3
/h 2.51 3.14 3.66
(ft
3
/h) (89) (111) (129)
Maximum DHW Output kW 26.1 32.7 38.2
DHW Flow Rate at
35°C temp. rise
l/min 10.7 13.4 15.7
DHW Specic Rate l/min 12.5 15.6 18.3
Table 2 - Performance Data - Central Heating Table 3 - Performance Data - Domestic Hot Water
Boiler Input: Max. Min.
26 33 38
Boiler Input ‘Q’ Nett CV kW 24.3 4.9 6.1 7.1
Gross CV kW 27.0 5.4 6.7 7.9
Gas Consumption m
3
/h 2.51 0.50 0.62 0.73
Boiler Output:
Non Condensing kW 24.2 4.8 6.1 7.1
70ºC Mean Water Temp.
Condensing kW 25.6 5.1 6.4 7.5
40ºC Mean Water Temp.
Seasonal Efciency*
SEDBUK 2005 91.1% 91.1% 91.1%
SEDBUK 2009 89.6% 89.6% 89.6%
NOx Classication CLASS 5
NOx Level (mg/kWh @ 0% 0
2) 26.4 28.1 35.3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL Logic Plus Combi C 24 and is the answer not in the manual?

IDEAL Logic Plus Combi C 24 Specifications

General IconGeneral
BrandIDEAL
ModelLogic Plus Combi C 24
CategoryBoiler
LanguageEnglish

Related product manuals