User Manual
18
3.3 Maintenance for Long Periods of Inacvity
In the winter, the product must be stored inside the vehicle, as it will not work at
temperatures near or below 0°C. When switching o the product for prolonged periods
of me, wait for complete defrosng and remove the condensaon that has formed.
To prevent damage to the product, electrical/mechanical components and/or the
formaon of mould. The natural defrosng me can vary from a few minutes to several
hours. When the product is shut o, the door should be le in venlaon posion and
all power disconnected.
4 Low voltage protecon
In order to prevent excessive baery depleon, a protecon device shuts o the
compressor in case of insucient voltage and turns it back on when the voltage in
the system increases aer the baeries have been charged.
System Voltage Shut-down
Voltage
Minimum Operang
Voltage
12V 9.6 (10.4) V 10.9 (11.7) V
24V 21.3 (22.8) V 22.7 (24.2) V
If the bridge is removed between C and P, the values indicated in the parentheses are
valid.
WARNINGS: Before switching on the product, always make sure that the
baeries are in opmal condion.