28
8 LEDs for diagnoscs
The electronic control unit has a troubleshoong funcon when a LED is connected
as shown below.
The number of ashes indicates the type of error.
Number of LED
Flashes
Type of Error Soluon
6 Defecve sensor (the sensor is defec-
ve or disconnected).
Re-connect the sensor and verify that
the compressor starts working again.
Replace sensor if the compressor does
not work.
5 Thermal protecon of the electronic
control unit.
(the electronic control unit overheats
if the refrigeraon system has become
overloaded or the environmental tem-
perature is too high)
Remove excess gas or increase venla-
on.
4 Minimum motor speed error.
(if the refrigeraon system has been
overloaded, the motor cannot maintain
minimum speed of approximately
1.850 RPM).
Remove excess gas.
3 Motor starng error
[the rotor is blocked or pressure inside
the refrigerant circuit is too high (> 5
bar)].
Defecve electronic control unit.
The rst operaon to aempt is to
replace the electronic control unit. Re-
place compressor if problem persists.
2 Fan short-circuited
(the fan absorbs more than 1A from
the electronic control unit).
Replace the fan.
1 Baery protecon
(voltage is outside the maximum and
minimum voltages).
Check power cable condions. Replace
with new cables if necessary. Check
baery condions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Indel Webasto Marine BI41 Dual and is the answer not in the manual?

Indel Webasto Marine BI41 Dual Specifications

General IconGeneral
BrandIndel Webasto Marine
ModelBI41 Dual
CategoryRefrigerator
LanguageEnglish

Related product manuals