Parameter Table
Parameter Parameter Name Setting Range Unit Default Commission
F9-23
Power-on time upon 3rd
fault
N.A N.A N.A -
F9-56
Temperature sensor
type
0: No temperature sensor
1: PT100
N.A 0 -
F9-57
Motor overheat
protection threshold
0~200 ºC 110 -
Group FC: multi-reference
Parameter Parameter Name Setting Range Unit Default Commission
FC-00 Reference 0 0.0 to 100.0 % 10.0% -
FC-01 Reference 1 0.0 to 100.0 % 100.0% -
FC-02 Reference 2 0.0 to 100.0 % 11.0% -
FC-03 Reference 3 0.0 to 100.0 % 12.0% -
FC-04 Reference 4 0.0 to 100.0 % 40.0% -
FC-05 Reference 5 0.0 to 100.0 % 13.0% -
FC-06 Reference 6 0.0 to 100.0 % 14.0% -
FC-07 Reference 7 0.0 to 100.0 % 15.0% -
FC-08 UPS reference frequency 0.0 to 20.0 % 10.0% -
Attention! F4-02 to F4-04 and F4-06 Multi-Reference
Preset Reference Selector - F4-02 F4-03 F4-04 F4-06
FC-00 : Reference 0 0 OFF OFF OFF OFF
FC-01 : Reference 1 1 ON OFF OFF OFF
FC-02 : Reference 2 2 OFF ON OFF OFF
FC-03 : Reference 3 3 ON ON OFF OFF
FC-04 : Reference 4 4 OFF OFF ON OFF
FC-05 : Reference 5 5 ON OFF ON OFF
FC-06 : Reference 6 6 OFF ON ON OFF
FC-07 : Reference 7 7 ON ON ON OFF