- 53 -
2 System Commissioning
2
2.2.7 Leveling Accuracy Adjustment
There are two leveling accuracy adjustment methods, described as follows:
1. All-oor adjustment
Parameter No. Parameter Name Setting Range Default
F4-00 Leveling adjustment 0–60 30
F4-00 is used to adjust the car stop position at all oors. The setting of F4-00 is effective to all oors.
Increase F4-00 if under-leveling occurs at every oor and decrease F4-00 if over-leveling occurs at
every oor.
3. Single-oor adjustment
Adjust the car stop position at each oor separately by setting group Fr parameters.
Parameter No. Parameter Name Setting Range Default Unit Property
Fr-00 Leveling adjustment function
0: Disabled
1: Enabled
0 -
Fr-01 Leveling adjustment record 1
00000–60060
30030 mm
Fr-02 Leveling adjustment record 2 30030 mm
Fr-20 Leveling adjustment record 20 30030 mm
The owchart of single-oor leveling accuracy adjustment is shown in the following gure.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance Monarch NICE300new Series and is the answer not in the manual?

Inovance Monarch NICE300new Series Specifications

General IconGeneral
BrandInovance
ModelMonarch NICE300new Series
CategoryController
LanguageEnglish

Related product manuals