3.3.1 UCMP Detection
Wiring
Figure 3-6 UCMP wiring for motor without auxiliary brake
SY
SO1
SO2
SX1
SX2
MCTC-SCB-A/
A1
Shorting door lock
circuit relay output
MCB
Door lock
shorting output
Y5
Up
re-leveling
Down
re-leveling
24V
COM
X27
Door lock
detection
FL
1
FL2
24V
COM
X2
X8
Door zone input
Shorting door
lock circuit relay
feedback input
Safety circuit
101
UCMP test switch
Hall door lock
Car door lock
X26
Door lock
shorting
detection
Without auxiliary brake (single door)