Intel® Server Board S2600CW Family TPS Power Supply Specification Guidelines
Revision 2.4
135
10.2.7 Thermal CLST
The power supply shall assert the SMBAlert signal when a temperature sensor crosses a
warning threshold. Refer to the Intel
®
Common Hardware and Firmware Requirements for CRPS
Power Supplier for detailed requirements.
10.2.8 Power Supply Diagnostic “Black Box”
The power supply saves the latest PMBus* data and other pertinent data into nonvolatile
memory when a critical event shuts down the power supply. This data is accessible by the
SMBus* interface with an external source providing power to the 12Vstby output.
Refer to the Intel
®
Common Hardware and Firmware Requirements for CRPS Power Supplier for
detailed requirements.
10.2.9 Firmware Uploader
The power supply has the capability to update its firmware by the PMBus* interface while it is
in standby mode. This FW can be updated when in the system and in standby mode and
outside the system with power applied to the 12Vstby pins.
Refer to the Intel
®
Common Hardware and Firmware Requirements for CRPS Power Supplier for
detailed requirements.

Table of Contents

Other manuals for Intel S2600CW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2600CW and is the answer not in the manual?

Intel S2600CW Specifications

General IconGeneral
BrandIntel
ModelS2600CW
CategoryServer Board
LanguageEnglish

Related product manuals