LED Keypad
DISARMING THE SYSTEM
When you enter the protected area through one of the designated Entry/Exit doors, the
keypad control will sound a continuous tone for the duration of the entry delay time, or
until you enter a valid code. The
away, stay
and
night keys
will go off and the tone will
stop. The security system is now DISARMED. If a valid code is not entered before the
end of the entry delay, an alarm will occur. (
NOTE:
If the
away, stay
or
night keys
are flashing during the entry delay, the alarm system has been activated in your
absence. Leave the building immediately and call your alarm company and/or the
police from a safe location
.)
ABORT FEATURE (Optional, see page 1)
The
abort light
will flash during an abort delay time. If a code is entered while this light
is flashing, all abortable reports will stop the communication process. Entering a code
during or after an alarm report to the central station will cause the
abort light
to come
on. It will stay on until the central station has received the cancel report.
TURNING THE DOOR CHIME ON AND OFF
The door chime is turned on or off by pressing [
7
]-[
1
] while the system is in the
disarmed state. If the chime is “on”, the
chime light
will be illuminated. If the chime is
“off”, the
chime light
will be off. Each time [
7
]-[
1
] is pressed it will toggle the chime
feature on/off and produce a momentary ding-dong sound.
BYPASSING ZONES
If you wish to bypass one or more zones, it must be done while the system is in the
disarmed state.
1.
Press [
BYPASS
].
2.
Enter user code, if required. The
bypass key
flashes.
3.
Enter the zone number you wish to bypass, i.e. press [
4
] for zone 4.
4.
Press [
BYPASS
] again.
5.
The corresponding
zone light
will illuminate indicating the zone has been
bypassed. Repeat steps 3 and 4 for any other zone(s) that need to be bypassed.
6.
Press [
BYPASS
] again -or- press [
#
] to exit the Bypass Mode. The
bypass key
will stop flashing upon exiting the Bypass Mode.