Page #138 background imageLoading...
Page #138 background image
Technical Specification
Temperature Coefficient
Temperature
Coefficient
Voltage Temperature
Coefficient
100ppm/℃
Current Temperature
Coefficient
50ppm/℃
Regulation
Load
Regulation
Voltage
≤0.05% Umax
Current
≤0.05% Imax
Line
Regulation
Voltage
≤0.05% Umax
Current ≤0.05% Imax
Ripple
Ripple
Voltage ≤600mVp-p
Current ≤30mArms
value voltage rise/fall time
Rise time
Voltage(No load)
20ms
Rise time
Voltage(Full load)
50ms
Fall time
Voltage(No load)
20ms
Fall time
Voltage(Full load)
20ms
Transient
Response
Time
Voltage
≤2mS
Output Protection range
OCP -6.2A or 6.2A
OVP 305V
OPP -410W or 410W
External analog (optional)
Voltage programming
External 0V~10V is 0~300V
Voltage monitoring
External 0V~10V is 0~300V
Current programming
External -10V~10V is -6A~6A
Current monitoring
External -10V~10V is -6A~6A
AC parameters
Voltage range
100VAC -240VAC
OVP 264VAC
UVP 90VAC
Frequency
47Hz~63Hz
Max. current (rms) 2Aac (AC220V)
DC Offset -0.1A~+0.1A
Copyright © Itech Electronic Co., Ltd.
127

Table of Contents

Other manuals for ITech IT-M3400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3400 Series and is the answer not in the manual?

ITech IT-M3400 Series Specifications

General IconGeneral
BrandITech
ModelIT-M3400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals