Multi-Machine Operation
a. Connect system bus interfaces.
b. Connect the DUTs. Refer to 2.5 Connecting the Device Under Test
(DUT) for more information about connection methods.
c. Connect the instrument to PC. refer to 2.6 Connect the Communication
Interface.
3. After power-on, if the interface prompts “Chan Number Conflict”, rotate the
knob to change the channel number directly.
8.2 Synchronized Function (Link)
By operating one unit in the System Bus link locally or remotely, it is possible to
synchronously control the On/Off and equal-scale output of the other units. The
synchronization function and On / Off Delay function can be used together to
realize the application of timing output.
Before configuring the synchronized function, each instrument must be set to
a separate channel number ranging from 1 to 16. refer to 8.1 Multi-Channel
Function .
There are three synchronized modes as follows:
On/Off Only: set multiple units to output on/off and Save/Recall
synchronization.
Track: besides output on/off and Save/Recall synchronization, you can set
the voltage proportional relation Reference among multiple power supplies
to make the voltage change proportionally. For example, set the voltage
proportional relation for three power supplies to 3, 4 and 5. If the voltage of
the first power supply is set to 30 V, the voltage of the other two power
supplies will change to 40 V and 50 V automatically.
This function requires multiple instruments to be in CV priority mode at the
same time, otherwise the voltage setting proportionally is not effective. Before
using this function set all units to CV priority mode.
Duplicate: in this mode, the synchronized operations includes: output on/off
synchronization, voltage/current setting value changing synchronization,
Save/Recall synchronization, priority mode synchronization, voltage/current
rising/falling synchronization and Protect menu function synchronization.
There are the following two synchronized status:
Copyright © Itech Electronic Co., Ltd.
96

Table of Contents

Other manuals for ITech IT-M3400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3400 Series and is the answer not in the manual?

ITech IT-M3400 Series Specifications

General IconGeneral
BrandITech
ModelIT-M3400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals