Functions and Characteristics
Copyright © ITECH Electronics Co., Ltd. 18
number(range from 1 to 50), press
to confirm.
7. You can recall the data stored before by pressing the register number.
Setting Communication Baud Rate (>BAUDRATE)
This function can help you set communication baud rate. There are 4 kinds of
baud rate, 4800HZ, 9600HZ, 19200HZ and 38400HZ. Make sure that power’s
baud rate is as the same as your computer before communication. Default baud
rate is 4800HZ.
Setting Communication Parity Bit (>Comm.Parity)
This function can set communication parity bit. There are three kinds of
communication parity bit, None, Even and Odd. Make sure that the communication
parity bit set to None during remote communication operation. Default
communication parity bit is None.
Setting Address (>ADDRESS)
This instruction can set the communication address for each power supply. The
address range is from 0 to 30. Before the communication, you must make sure that
there is same address between the power supply and the computer. Default
address is 0.
Option:
1. Press
+
into menu operation, VFD displays Config,
press
to confirm.
2. VFD displays Address= **, select to and set address,
press
to confirm.
3. Press
two times to escape menu operation.
Setting Port Mode
The level of the port on the rear panel is TTL, and the port has 3 kinds of function
as follows:
TRIGGER: pin1 and pin 2 can be used as the external trigger source for power
supply, and can control the list operation.
RI/DFI: Inhibit Input can control the output state of power supply, Fault Output can
find fault of power supply.
DIGITAL I/O: It can read and control output and input state.
mode
Pin
Trigger RI/DFI DIGITAL I/O