IT6700 User manual
User Manual
27
SN-1 XXXXXX
the first six number of SN
SN-2 XXXXXX
the middle six number of SN
SN-3 XXXXXX
the last six number of SN
EXIT
Exit the information menu
EXIT MENU
Exit the main menu
NotePressing
ESC
button can enable you to quit any function setting.
5.9.2 Menu functions
Maximum voltage setMAX VOLT
The range of setting voltage is from 0V to rated voltage. You can press
(Shift)+
I-setI-set
(Menu) button to enter the menu, then press key to select >MAX
VOLT item. Press
Enter
button to confirm. After you set the max voltage value, the output
voltage value can only be set within the max voltage. The default max voltage value is the
rated value.
Over current protection set(OCP SET)
Over current protection feature allows the user to set an over current protection point, when
the current in the circuit is larger than the current protection point, the power supply will
enter OCP protection. Over current protection, power output will be off, and accompanied by
the chirping of the buzzer, the VFD mark Prot will be lit, and the emergence of "OVER
CURR" alarm
The operation to set the OCP point:
Press
(Shift)+
I-setI-set
Menubutton to menu, press to overturn to OCP SET
press
Enter
buttonand to select ONpress
Enter
to confirm, set OCP point by
pressing numeric keys, then press
Enter
. At last, press to escape.
Power-on parameters set (P-MEM)
This item can set power on parameters. If you select RESET item, then all the
parameters will be initialized to the factory setting. Output voltage and current will always be
0V/max rated current; if set to Keep, the output value will be the same with last power off
state. The default setting is RESET item.
Power On Output State(P-OUT )
This item can set the power on output state. If you select KEEP item, that indicates the
power on output state is the same with output state before this item is set. If you select Off
item, unit will automatically in off mode when you power on. Default setting is Off item.