Chapter1 Inspection and Installation
Power supply is a high level safety equipment, there is a protected ground terminal.
Before Installation or operation, please read the safety signs and instructions in this manual
1.1 Inspection
After received the power supply, follow these steps to check it:
1. Check for damage in the equipment during transport
If it is the frame, panel damaged, or abnormal working, etc. Please contact immediately with
our authorized dealer or service department. Do not return the instrument before positive
response has not been got.
2. Check the attachment
Make sure you receive the power and the following components at the same time, if any
missing, please contact your nearest dealer.
□ a power cord (in accordance with the standard voltage used in the region)
□ an operating manual.
□ a factory calibration report
Kinds of power cord
E
NL
E
LN
E
NL
E
LN
China USA ,Canada Europe UK
IT-E171 IT-E172 IT-E173 IT-E174
3. The power input requirements
Working voltage for IT6723/IT6723B/IT6723C/IT6723H/IT6723G is 110V and 220V;Working
voltageforIT6724/IT6724B/IT6724C/IT6724H/IT6724G/IT6726H/IT6726G/IT6726V/IT6726B
is 220V, so please pay attention to the working input voltage. There is a power cord which
matches with your local power in the attachment. If that does not match, please do not
hesitate to contact with our authorized dealer or service department.
AC input levels : (can choose via the switch on the bottom or power supply)
Option Opt.01:220VAC ± 10%, 47 to 63 Hz
Option Opt.02:110VAC ± 10%, 47 to 63 Hz
1.2 To Rack Mount the Instrument
You can mount IT6700 power supply in a standard 19-inch rack cabinet using the IT-E151
(except for IT6726H/IT6726G/IT6726V/IT6726B) rack mount kit.
Method to remove the handle:
Pull up carrying handle to each outside, rotate it to vertical direction and pull out.