Measurement Commands
Copyright © Itech Electronic Co., Ltd. 37
MEASure[:SCALar]:FREQuency?
This command is used to read the current output frequency value.
Command syntax
MEASure[:SCALar]:FREQuency?
Returns
<NR2>
MEASure[:SCALar]:CURRent[:AC]:PEAK?
This command is used to read the current peak output current.
Command syntax
MEASure[:SCALar]:CURRent[:AC]:PEAK?
Returns
<NR2>
MEASure[:SCALar]:CURRent[:AC]:PEAK:MAXimum?
This command is used to read the current maximum peak current.
Command syntax
MEASure[:SCALar]:CURRent[:AC]:PEAK:MAXimum?
Returns
<NR2>
MEASure?
FETCh?
This command is used to read the measurement frequency, RMS voltage, RMS
current, active power measurement, power factor measurement, apparent
power measurement, peak current measurement, maximum peak current
measurement.
Parameters
None
Note: The FETCh and MEASure instructions also read various parameter values, except that
FETCh reads the last measured value and MEASure is the re-measured value. FETCh
speed faster, but the accuracy of MEASure higher.

Table of Contents

Other manuals for ITech IT7321

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7321 and is the answer not in the manual?

ITech IT7321 Specifications

General IconGeneral
BrandITech
ModelIT7321
CategoryPower Supply
LanguageEnglish

Related product manuals