IEEE488.2 Common Commands
Copyright © Itech Electronic Co., Ltd. 56
*ESR?
This command can read the value of standard event status register. After
executing this command, standard event status register is reset. Bit
definition of standard event status register is as the same as the
standard event status enable register.
Query syntax
*ESR?
Parameters
None
Returns
<NR1>
Related commands
*CLS *ESE *ESE? *OPC
*IDN?
This command is used to query related information of AC power.
Query syntax
*IDN?
Arguments
None
Returns
<string>
Example
*IDN?
*OPC
When all commands before this command are executed, bit OPC in
standard event register will be set to 1.
Command syntax
*OPC
Arguments
None

Table of Contents